Decorative Hanging Linear Fixture

2 fixtures per channel
15% – 100%
infoMax Cat6 run length per fixture qty at full output. Assumes a 57 V X-PoE input.
│ CH1+ ────── LED+
X-PoE ─── XPD IN │ CH1- ────── LED-
┌─── XPD OUT │ CH2+ ────── (unused)
│ │ CH2- ────── (unused)
│
└── (to additional XPDs / fixtures)
Notes:
• Manufacturers may need to ship some fixtures wired to CH2 instead of CH1 — verify before install.infoRecommended starting values. Actual settings may need to be tuned for real-world conditions.
Settings shown are per individual fixture segment. Multiple segments may be combined into a single fixture. When multiple segments share a common power feed, X-PoE channels must be aggregated to provide up to 2,230mA of output current.